Ao-smith DB/DW-720-1810 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Chaudière à eau Ao-smith DB/DW-720-1810. A.O. Smith DB/DW-720-1810 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 44
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
1
WITH ELECTRONIC INTERMITTENT PILOT IGNITION AND
INSTALLATIONS
WARNING: If the information in this manual
is not followed exactly, a fire or explosion may
result causing property damage, personal
injury or loss of life.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
· Do not try to light any appliance.
· Do not touch any electrical switch;
do not use any phone in your
building.
· Immediately call your gas supplier
from a neighbors phone. Follow
the gas suppliers instructions.
· If you cannot reach your gas
supplier, call the fire department.
Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
PRINTED IN U.S.A. 2221 0302
CAUTION
TEXT PRINTED OR OUTLINED IN RED CONTAINS
INFORMATION RELATIVE TO YOUR SAFETY.
PLEASE
READ THOROUGHLY BEFORE INSTALLING AND
USING THIS APPLIANCE.
PART NO. 211680-000 REV. 00
SUPERSEDES PART NO. 200311-000 REV. 4 & 210265-000 REV. 0
Built tough with maximum efficiency
TM
A DIVISION OF A.O.SMITH CORPORATION
EL PASO, TX McBEE, SC RENTON, WA
STRATFORD, ONTARIO
VELDHOVEN, THE NETHERLANDS
www.hotwater.com
PLACE THESE INSTRUCTIONS ADJACENT TO BOILER AND
NOTIFY OWNER TO KEEP FOR FUTURE REFERENCE.
MODELS DB/DW-720-1810
NATURAL GAS-FIRED COMMERCIAL CROSS FLOW COPPER BOILERS
FOR HYDRONIC HEATING AND HOT WATER SUPPLY
INSTALLATION OPERATION MAINTENANCE LIMITED WARRANTY
Vue de la page 0
1 2 3 4 5 6 ... 43 44

Résumé du contenu

Page 1 - MODELS DB/DW-720-1810

1WITH ELECTRONIC INTERMITTENT PILOT IGNITION AND INSTALLATIONSWARNING: If the information in this manualis not followed exactly,

Page 2 - CONTENTS

10TABLE 5Multipliers To Be Used With Table 1 When Applying TheGravity Factor To Other Than .60 Specific GravitySpecific SpecificGravity Multiplier Gr

Page 3 - CAPACITIES

11Applications of the gravity factor converts the figures given in table1 to capacities with another gas of different specific gravity. Suchapplicati

Page 4 - WARNING

12IF ANY OF THE ORIGINAL WIRE, AS SUPPLIED WITH THEAPPLIANCE, MUST BE REPLACED, IT MUST BE REPLACEDWITH TYPE 105°C WIRE OR ITS EQUIVALENT, EXCEPT FORT

Page 5 - FEATURES

13The flow switch shall be mounted in the top opening of the reducingtee and provide adequate paddle length in the flow stream. Forexample in a 2&quo

Page 6 - SAFETY FLOW SWITCH

14Thereafter, during the heating season, lubricate the three oil cupsat least once every four months. Combination heating/coolingsystems or water hea

Page 7 - INSTALLATION INSTRUCTIONS

15A system bypass should be installed as shown in fig. 10 to preventboiler circulation starvation when the system zones call for reducedflow.This bypa

Page 8 - VENTING THE BOILER

16NOTES:1. BUILDING TEMPERATURE CONTROLS SUPPLY ELECTRIC POWER TO BUILDING CIRCULATOR.2. MAIN FLOW SWITCH PROVES MAIN WATER FLOW BEFORE ENERGIZING, SE

Page 9 - GAS CONNECTIONS

17BYPASS BALANCINGWith systems where water temperature can be expected to dropappreciably due to long standby periods, or heavy draw down, abypass pip

Page 10

18generator type boilers establish temperature rises. The decidingfactor in choice of boiler temperature rise relates to the boiler inlettemperature.

Page 11 - WIRING CONNECTIONS

19FIGURE 14NO. SUGGESTED ITEMS FOR INSTALLATION 1. SHORT PIPE NIPPLE AND PAIR OF BOILER LOOP TEES INPIPING BETWEEN SYSTEM SUPPLY AND RETUR

Page 12 - INSTALLATION

2FOREWORD CAUTIONTEXT PRINTED OR OUTLINED IN RED CONTAINSINFORMATION RELATIVE TO YOUR SAFETY. PLEASE READTHOROUGHLY BEFORE USING APPLIANCE.Detailed

Page 13 - CIRCULATING PUMP

20USE ONY TYPE 105°C THERMOPLASTIC OR ITS EQUIVALENTIF ANY OF THE ORIGINAL WIRES AS SUPPLIED MUST BE REPLACED.USE ONY TYPE 105°C THERMOPLASTIC OR ITS

Page 14 - SYSTEM INSTALLATION

21DURA-MAX - PUMP MOUNT - SINGLE STAGE - SCHEMATIC DIAGRAMDURA-MAX - SINGLE STAGE FIRING - UNITED STATES MODELS WITH PUMP.120 VOLT SYSTEM CONTROLLER

Page 15 - DB INSTALLATION

22DURA-MAX - PUMP MOUNT - DUAL STAGE - SCHEMATIC DIAGRAMDURA-MAX - DUAL STAGE FIRING - UNITED STATES MODELS WITH PUMP.120 VOLT SYSTEM CONTROLLER

Page 16

23DURA-MAX - PUMP MOUNTED - MODULATING - SCHEMATIC DIAGRAMDURA-MAX - MODULATED FIRING - UNITED STATES MODELSWITH PUMP. 120 VOLT SYSTEM CONTROLLER

Page 17 - BYPASS BALANCING

24DURA-MAX - SINGLE STAGE FIRING - SCHEMATIC DIAGRAMDURA-MAX - SINGLE STAGE FIRING - UNITED STATES & CANADIAN MODELSWITHOUT PUMP. 120 VOLT SYSTEM

Page 18

25DURA-MAX - DUAL STAGE FIRING - SCHEMATIC DIAGRAMDURA-MAX - DUAL STAGE FIRING - UNITED STATES & CANADIAN MODELSWITHOUT PUMP. 120 VOLT SYSTEM CON

Page 19 - FIGURE 14

26DURA-MAX - MODULATED FIRING - SCHEMATIC DIAGRAMDURA-MAX - MODULATED FIRING - UNITED STATES & CANADIAN MODELSWITHOUT PUMP. 120 VOLT SYSTEM CONTR

Page 20 - FIGURE 16

27HOT WATER SUPPLY APPLICATIONSCer-Temp 80 Recovery SystemsWATER LINE CONNECTIONSThis section provides detailed installation diagrams for typicalmetho

Page 21 - 120 VOLT SYSTEM CONTROLLER

28ONE DURA-MAX (MODEL DW) COMMERCIAL BOILER WITH HORIZONTAL TANK CAUTIONTO PREVENT CONDENSATION THE MINIMUM BOILER INLET TEMPERATURE IS 100°F (38°C

Page 22

29TWO DURA-MAX (MODEL DW) HOT WATER SUPPLY BOILERS WITH VERTICAL TANK CAUTIONTO PREVENT CONDENSATION THE MINIMUM BOILER INLET TEMPERATURE IS 100°F (38

Page 23

3 WARNINGAN AMPLE SUPPLY OF AIR MUST BE PROVIDEDFOR PROPER COMBUSTION AND VENTILATION.Minimum Clearances To CombustiblesWater BlankTop Side Side Re

Page 24

30TWO DURA-MAX (MODEL DW) HOT WATER SUPPLY BOILERS WITH HORIZONTAL TANK CAUTIONTO PREVENT CONDENSATION THE MINIMUM BOILER INLET TEMPERATURE IS 100°

Page 25

31FIGURE 24MANIFOLDING OF MODEL TJV-120M & TJV-200M TANKSNOTE: PIPE SIZES BETWEEN MANIFOLDS AND BOILER(S) TOBE SELECTED FROM THE CER-TEMP 80 DIAGR

Page 26

32START-UP AND OPERATINGINSTRUCTIONS WARNINGAfter placing boiler into operation, the ignition system safety shutoffdevice must be tested by the fol

Page 27 - HOT WATER SUPPLY APPLICATIONS

33LIGHTING AND OPERATING INSTRUCTIONS WARNING:HOT WATER CAN PRODUCE 3rd DEGREE BURNS IN 6 SECONDS AT 140° F. (60° C).IN CASE OF POWER FAILURE DO NO

Page 28 - CAUTION

34INTERNAL CONTAMINANTSThe system must be internally cleaned and flushed after a new orreplacement unit has been installed to remove contaminants that

Page 29 - CAUTION

351. Remove main burners from unit.2. Check that burner venturi and ports are free of foreign matter.3. Clean burners with bristle brush and/or vacuum

Page 30

36 CHECKING HONEYWELL S8600H OR S8610M (NAT. GAS) INTERMITTENT IGNITION CONTROLS NO SPARK AT PILOT BURNERNOReplace ignition module Is voltage (2

Page 31 - FIGURE 24

37 SPARK AT PILOT BURNER BUT PILOT WILL NOT LIGHTEnsure all manual shutoff valves are fully open; All filters are clean;All gas connections are gas

Page 32 - INSTRUCTIONS

38 PILOT BURNER LIGHTS BUT MAIN BURNER DOES NOT LIGHTCorrect the situation by consulting NOthe installation or user’s manual Does the pilot fla

Page 33 - TO TURN OFF GAS TO APPLIANCE

39 CAUTIONDO NOT USE A NYLON BRUSH OR OTHER STATIC CREATINGMATERIAL TO CLEAN DUST AND CARBON DEPOSITS FROMHEATING SURFACES AND VENT.SUCH DEPOSITS A

Page 34 - MAIN BURNER

4 WARNINGYour Dura-Max boiler is not designed to operate with a boiler inlet water temperature of less than100°F (38°C). Colder inlet water temper

Page 35 - TROUBLE-SHOOTING

40The time between cleaning will vary from two to six monthsdepending upon water conditions and usage. A change ofapproximately 5°F in the normal tem

Page 36

41DURA-MAX LIMITED WARRANTYA. O. Smith Corporation, the warrantor, extends the following LIMITED WARRANTY to the owner of this hydronic boiler:1. If w

Page 39 - GENERAL MAINTENANCE

44REPLACEMENT PARTS5621 W. 115TH STREET, ALSIP, IL 60803PHONE: 800-433-2545 FAX: 800-433-2515www.hotwater.com E-Mail: [email protected]

Page 40 - •LIME REQUIRED

5FEATURESIMPORTANTOnly qualified personnel shall perform the initial firing of the heater.At this time the user should not hesitate to ask the individ

Page 41 - DURA-MAX LIMITED WARRANTY

6AUTOMATIC RESETHIGH TEMPERATURE LIMIT CONTROL CAUTIONLIMIT CONTROLS ARE NOT TO BE USED AS THERMOSTATS.ALL MODELS - This limit is a safety device

Page 42

7INSTALLATION INSTRUCTIONSREQUIRED ABILITYINSTALLATION OR SERVICE OF THIS BOILER REQUIRESABILITY EQUIVALENT TO THAT OF A LICENSED TRADESMANIN THE FIEL

Page 43

8If the confined space is within a building of tight construction, air forcombustion, ventilation, and draft hood dilution must be obtainedfrom outdoo

Page 44

9 WARNINGFAILURE TO CORRECT BACK DRAFTS MAY CAUSE AIRCONTAMINATION AND UNSAFE CONDITIONS.Vent connectors serving appliances vented by natural draft s